Get Quote

INVERTER MODULE

HTP III 48-120AC-2000

Beijing High-tech Dynamic Power
HTP III 48-120AC-2000 Inverter Module

Introduction

HTP III 48-120AC-2000 is a digital inverter module. It is specially designed for telecom, network access and energy storage system applications and so on. It can work with outstanding reliability. HTP III 48-120AC-2000 supports parallel connection, and can also be used in 3-phase Y-type system.

Features

  • Digital control: Digital primary and secondary control, realizing excellent monitoring and regulation.
  • High reliability design: One fan front-to-back airflow with latest thermal solution and experienced design.
  • Excellent EMC performance: Lower interference and excellent susceptibility give the module better compatibility.
  • Global approvals: Meets CE standards.
DC Input
Input Voltage Range 42-58VDC (Nominal: 53.5VDC)
Maximum Input Current 56A rms
Output
Voltage 90-140VAC (Nominal 120VAC)
Rated Current 13.3A at 120VAC, resistive load
Frequency 50/60Hz
Frequency Stability ≤1%
Static Voltage Regulation ≤1%
Dynamic Voltage Regulation ≤10% (recovery time ≤60ms)
THDv ≤3%, rated resistive load; ≤6%, rated non resistive load
Load Power Factor Requirement ≥0.8
Peak Efficiency ≥92.6%
Current Sharing ≤5%
Output Power 2000VA/1600W (46-58VDC)
50-58Vin Output Overload Capacity (Resistive load) 105%≤Load≤125%, t≥10min; 125%<Load≤150%, t≥10S; Load>150%, t≤1S
42-50Vin Output Overload Capacity (Resistive load) 105%≤Load≤125%, t≥1min; Load>125%, t≤1S
Crest Factor ≥3@140Vo/2000VA

HTP III 48-120AC-2000 — INVERTER MODULE

Other Specifications
Operating Temp. -20℃ ~ 75℃
Storage Temp. -40℃ ~ 85℃
Relative Humidity <90% (non-condensing)
Altitude 4000m (Derating > 2000m)
IP Level IP20
Input Protection Input fuse protection, Under/Overvoltage shutdown
Output Protection Under/Overvoltage shutdown, short circuit protection, output fuse protection, 5KA lightning protection
Isolation 4242VDC-input and output; 2121VDC-output and earth; 707VDC-input and earth
Paralleling Up to 12 modules in parallel
Fan Speed Temperature and output current regulated
MTBF ≥500,000 hours (T_ambient: 25℃), Telcordia SR-332 Issue 1
Acoustic Noise ≤55dB at rated input and output, full load (T_ambient: < 30℃)
Dimensions 107W x 40.8H x 270D (mm)
Weight 2.0Kg
Applicable Standards
Safety UL 1741, EN/IEC 62477-1:2012, EN/IEC 62368-1
EMC EN55032 Class B (emission)
EN IEC-6-4:2019, IEC 61000-6-4:2018
EN 61000-3-12:2011, IEC 61000-3-12:2011
EN IEC 61000-3-11:2019, IEC 61000-3-11:2017
EN IEC 61000-6-2:2019, IEC 61000-6-2:2016
IEC61000-3-2, IEC61000-3-3
IEC61000-4-2 (electrostatic discharge), IEC61000-4-3 (radiated immunity), IEC61000-4-4 (EFT), IEC61000-4-5, IEC61000-4-6 (conducted immunity), IEC61000-4-8, IEC61000-4-11
Environment ETSI EN 300 019-2 (-1,-2,-3)
ETSI EN 300 132-2

Diagrams

HTP III 48-120AC-2000 Fig 1: output power vs. input voltage; Fig 2: output power vs. ambient temp.
HTP III 48-120AC-2000 Fig 3: output power vs. output voltage; Fig 4: efficiency vs. load (at 53.5V input)