Get Quote

INVERTER MODULE

HTP III 48-220AC-3000

Beijing High-tech Dynamic Power
HTP III 48-220AC-3000 Inverter Module

Introduction

HTP III 48-220AC-3000 is a digital inverter module. It is specially designed for telecom, network access, energy storage systems, and similar applications. It can work with outstanding reliability, efficiency and high power density. HTP III 48-220AC/3000 supports parallel connection and can also be used in a 3-phase Y-type system (via monitor settings).

Features

  • Digital control: Digital primary and secondary control, realizing excellent monitoring and regulation.
  • High reliability design: One fan front-to-back airflow with latest thermal solution and experienced design.
  • Excellent EMC performance: Low emissions and excellent immunity provide better compatibility.
  • Global approvals: Meets applicable CE standards.
DC Input
Input Voltage Range 42-58VDC (Nominal: 53.5VDC)
Maximum Input Current 75A
Output
Voltage 200-230VAC (Nominal 220/230VAC)
Rated Current 10.9A at 220VAC, resistive load
Frequency 50/60Hz
Frequency Stability ≤1%
Static Voltage Regulation ≤1%
Dynamic Voltage Regulation ≤10% (recovery time ≤60ms)
THDv ≤3%, rated resistive load; ≤6%, rated non-resistive load
Load Power Factor Requirement ≥0.8
Efficiency ≥94% @53.5Vin/220Vo/50%load
Current Sharing ≤5%
Rated Output Power 3000VA/2400W (46-58VDC); 2500VA/2000W (other input)
46-58Vin Output Overload Capacity (Resistive load) 105%≤Load≤125%, t > 1min; Load > 125%, t≤1s
42-46Vin Output Overload Capacity (Resistive load) 105%≤Load≤125%, t > 10min; Load > 125%, t≤1s; 125% < Load≤150%, t > 10s

HTP III 48-220AC-3000 — INVERTER MODULE

Other Specifications
Operating Temp. -20℃ ~ 75℃
Storage Temp. -40℃ ~ 85℃
Relative Humidity <90% (non-condensing)
Altitude 4000m (Derating > 2000m)
IP Level IP20
Input Protection Input fuse protection, Under/Overvoltage shutdown
Output Protection Under/Overvoltage shutdown, short circuit protection, output fuse protection, 5 kA lightning protection
Isolation 4242VDC-input and output, 2121VDC-output and earth, 707VDC-input and earth
Paralleling Up to 12 modules in parallel
Fan Speed Temperature and output current regulated
MTBF >500000 hours (T_ambient: 25℃), Telcordia SR-332 Issue 1
Acoustic Noise ≤ 55dB at rated input and output, full load (T_ambient: < 30℃)
Dimensions 107W x 40.8H x 270D (mm)
Weight 2.0Kg
Applicable Standards
Safety IEC 62477-1, UL 62368-1
EMC EN 55032 Class B (emission)
IEC 61000-3-2
IEC 61000-3-3
IEC 61000-4-2 (electrostatic discharge)
IEC 61000-4-3 (radiated immunity)
IEC 61000-4-4 (EFT)
IEC 61000-4-5 (surge immunity)
IEC 61000-4-6 (conducted immunity)
IEC 61000-4-8
IEC 61000-4-11
Environment ETSI EN 300 019-2 (-1, -2, -3)
ETSI EN 300 132-2

Diagrams

HTP III 48-220AC-3000 diagrams: output power vs input voltage and vs ambient temperature