Get Quote

DC POWER SYSTEMS

HT SYS E2121300R48 Embedded Power System

Beijing High-tech Dynamic Power
HT SYS E2121300R48 Embedded Power System

Introduction

  • HT SYS E2121300R48 system is a compact and intelligent power system, It can house up to 4x3KW rectifiers and HT503 or HT505 controller.
  • Dry contact uses front access and front operation.
  • AC input and DC output use rear access and rear connection.
  • Compact design for easy installation.
  • Two levels of Low Voltage Disconnect (LVD) protection.
  • Two battery MCBs (Miniature Circuit Breakers).
  • Compatible with rectifiers of the same size.

Applications

  • Fiber optic network
  • Access network
  • Satellite communication ground station
  • Transmission equipment
  • Mobile communication
  • ESS (Energy Storage System)

Features

  • 19" 2U sub-rack, easy to be embedded into all standard telecom equipment
  • Up to 12kW system capacity
  • Up to 0.99 power factor
  • Intelligent fan-cooling
  • Rectifier modules hot-swap
  • N+1 rectifier module redundancy
  • Advanced batteries monitoring and management
  • ECO mode
  • High power density

Applicable Standards

Applicable Standards
Electrical IEC 60950-1, EN 60950-1, UL 60950-1
EMC EN 55022 Class A
Environmental ETSI EN 300 019-2, ETSI EN 300 132-2, RoHS

HT SYS E2121300R48 Embedded Power System — DC POWER SYSTEMS

Input
AC Input 85Vac-300Vac
Input Current ≤15A (Per rectifier)
Frequency 45~65Hz
THDi <5%@full load, <10%@half load, Rated input and output voltage
Output
Output Voltage -53.5V Rated output voltage
Output Current -53.5V float voltage, -56.4V boost voltage, ≥120A
Voltage Regulation ≤±1%
Current Sharing ≤±5%
Efficiency ≥92%
Ripple and Noise ≤200mV Peak-Peak
Psophometric Noise ≤2mV
Other Specifications
Operating Temperature -40 ℃ to +70 ℃ (-40 ℉ to +158 ℉)
Storage Temperature -40 ℃ to +85 ℃ (-40 ℉ to +185 ℉)
Humidity Operating: ≤95% non-condensing, Storage: ≤99% non-condensing
Dimensions(mm) 482.6W(19") x 88.1 H (2U) x 395D
Weight ≤10kg (Without rectifier)
Options
DC Distribution LLVD:1×150A/2P, BLVD:1×150A/2P, 2 MCBs for battery, the rating of load MCB is 100A BLVD & LLVD1, Rear operation and rear connection
AC Distribution Connect to backplane directly, Rear access and rear connection
Low Voltage Disconnect 150A Bi-stable contactors should be used as BLVD & LLVD1
Output Protection Short-circuit protection, Overload protection
Rectifier HT Power II 48 3000HE
Monitoring
Function Operation information acquirements, battery and system management, system alarm, communicate with control center related ports
Controller HT503 or HT505
Dry Contact 6 relay outputs, NO+COM
Digital Input 6 DI
Interface LCD
Temp Sensor 1
Battery Mid-Point 2 x Battery mid-point