DC POWER SYSTEMS

HT SYS E3601500R48 Power System

Beijing High-tech Dynamic Power
HT SYS E3601500R48 Power System

Introduction

  • HT SYS E3601500R48 system is a compact and intelligent power system, It can house up to 12*3KW rectifiers and 1*HT505 controller.
  • AC input, DC output and dry contact use front access and front operation.
  • With compact design, easy installation.
  • Two levels Low Voltage Disconnect (LVD) protection.
  • Eight battery MCBs.

Features

  • 19"10U sub-rack, easy to be embedded into all standard telecom equipment.
  • Up to 36kW system capacity.
  • Up to 0.99 power factor.
  • Intelligent fan-cooling.
  • Rectifier modules hot-swap.
  • Advanced batteries monitoring and management.
  • ECO mode.
  • High power density.

Applications

  • Fiber optic network
  • Access network
  • Satellite communication ground station
  • Transmission equipment
  • Mobile communication
  • ESS

Applicable Standards

Applicable Standards
Electrical IEC 60950-1; EN60950-1; UL 60950-1
Environmental ETSI EN 300 019-2; ETSI EN 300 132-2; RoHS

HT SYS E3601500R48 Power System — DC POWER SYSTEMS

Input
AC Input Tolerance: 85-300 Vac; Nominal: 176-300 Vac
Input Current ≤19A (Per rectifier)
Frequency 45~65Hz
THDi <5%@half load~full load; Rated input and output voltage
Output
Output Voltage 54Vdc (42~58Vdc adjustable)
Output Current 600A
Voltage Regulation ≤±1%
Current Sharing ≤±5%
Efficiency ≥Typical 96%
Ripple and Noise ≤200mV Peak-Peak
Psophometric Noise ≤2mV
Other Specifications
Operating Temperature -40°C to +70°C (-40°F to +158°F)
Storage Temperature -40°C to +85°C (-40°F to +185°F)
Humidity Operating: ≤95% non-condensing; Storage: ≤99% non-condensing
Altitude(m) ≤2000
Dimensions(mm) 482.6W (19") x 336D x 443.2H
Weight 33kg ≤ (Without rectifier)
Options
DC Distribution LLVD: 63A*9+16A*2, MCBs; BLVD: 125A*10, MCBs; Battery: 125A*8, MCBs; Front operation and front connection
AC Distribution AC input: 125A/3P*1+N terminal, MCB; AC Output: 32A/1P+N*1, MCB; Front access and front connection.
Low Voltage Disconnect 400A Bi-stable contactors should be used as LLVD and 200A Bi-stable contactors should be used as BLVD.
Output Protection Short-circuit protection; Overload protection
Rectifier HTP III 48-3000HE
Monitoring
Function Operation information acquirements, battery and system management, system alarm, communicate with control center related ports.
Controller HT 505
Dry Contact 12*DO(NC+COM)
Digital Input 12*DI
Display LCD
Temperature sensor Interface 4
Water Sensor Interface 1
Smoke Detectors 1